Sunday, April 1, 2012

Testing MS12-020

Testing MS12-020 on Windows 7 + Up-to-date SEP.

This video has been prepared for to inform users about this type of attack and direct them to take care about this attacks. Do not use this method to damage any systems.


Read more...

Monday, February 6, 2012

Metasploit & MS08_067



This video has been prepared for to inform users about this type of attack and direct them to take care about this attacks. Do not use this method to steal somebodys account information,  personal informations or damage systems.

Bu video, Sadece antivirus kullanımının yeterli olmadığı, bilgisayarlarımız üzerinde güvenliğinin sağlanması için kişisel güvenlik duvarı kullanılması gerektiğini ve tüm işletim sistemi ve yazılımların güncellemelerinin yapılması gerektiği konusunda bilgilendirmek için hazırlanmıştır.
Read more...

Thursday, July 7, 2011

SQL Server replication requires the actual server name to make a connection to the server. Connections through a server alias, IP address, or any....

"SQL Server replication requires the actual server name to make a connection to the server. Connections through a server alias, IP address, or any other alternate name are not supported."

Cause : the server name has been changed after SQL Server Installation

Resolution : You can change the server name in SQL server by using the code below; Execute in SSMM.

sp_dropserver 'old_server_name'(Ex : oldserver\instance)
GO
sp_addserver 'current_computer_name'Ex : newserver\instance), 'local'
Read more...

Thursday, June 2, 2011

Last Backup Date of SQL DBs

SELECT sdb.Name AS DBName,
COALESCE(CONVERT(VARCHAR(20), MAX(bus.backup_finish_date), 100),'No Backup Yet') AS LastBackUpDate FROM sys.sysdatabases sdb LEFT OUTER JOIN msdb.dbo.backupset bus ON bus.database_name = sdb.name
GROUP BY sdb.Name
Read more...

Friday, May 27, 2011

CLARiiON AX4 Storage Systems Feature Summary


Read more...

CLARiiON CX4 Storage Systems Feature Summary


Read more...

Thursday, May 26, 2011

Vmware ESX4.1 Add ISCSI Storage

Follow the steps below to create new VMKERNEL Connection to use with ISCSI adapter.
If you dont do the steps below and try to add iscsi target from dynamic discovery
You will see the message

"The host bus adapter is not associated with a vmknic. To configure targets the adapter should be associated with a vmknic. Refer to the VMware documentation to associate the adapter with a vmknic."







Procedure



1 Log in to the vSphere Client and select the host from the inventory panel.
2 Click the Configuration tab and click Networking.
3 In the Virtual Switch view, click Add Networking.
4 Select VMkernel and click Next.
5 Select Create a virtual switch to create a new vSwitch.
6 Select a NIC you want to use for iSCSI traffic.
7 Click Next.
8 Enter a network label.
Network label is a friendly name that identifies the VMkernel port that you are creating, for example,
iSCSI.
9 Click Next.

IMPORTANT If you are creating a port for the dependent hardware iSCSI adapter, make sure to select the NIC that corresponds to the iSCSI component.

Use the vSphere CLI command to determine the name of the physical NIC, with which the iSCSI adapter is associated.(You should press Alt+F1 for command mode on esx)
Alt + F2 turn back)






esxcli swiscsi vmnic list -d vmhba#
vmhba# is the name of the iSCSI adapter.


You might be enable TEch Support mode to execute the commands above;


Enabling and Accessing Tech Support ModeTo enable local or remote TSM from the Direct Console User Interface (DCUI):
1.At the DCUI of the ESXi host, press F2 and provide credentials when prompted.
2.Scroll to Troubleshooting Options, and press Enter.
3.If you want to enable local TSM, select Local Tech Support and press Enter once. This allows users to login on the virtual console of the ESXi host.

If you want to enable remote TSM, select Remote Tech Support (SSH) and press Enter once. This allows users to login via SSH on the virtual console of the ESXi host.
4.Optionally, if you want to configure the timeout for TSM:

a.Select Modify Tech Support timeout and press Enter.
b.Enter the desired timeout value in minutes and press Enter.

6.Press Esc three times to return to the main DCUI screen.


After you have done the above 9 steps configuration- networking tab should be like picture below;


Before adding to ESX server you should create target and LUNs on ISCSI device.


After this open Configuration Tab and select storage adapters from left menu.


Select the appropirate hba from the right menu and click properties and add IP and port (default 3260) of ISCSI device to dynamic discovery tab and 2-10 seconds later control the static discovery tab if the address added correctly






LUNs that you have created on ISCSI device should be visible on the below part like "QNAP ISCSI Disk (naa....) on the picture.



After adding ISCSI device IP, we should add LUNs as a storage to ESX server.



Open Configuration Tab- Select Storage from the left menu. Select AddStorage from right side.

Select Disk / LUN form the opened window click next.
Select the LUN that you will use as a datastore. Click Next give Name ex: "DRSQLSERVER"


Next,next,finish.


Then on previous screen click refresh to see your new datastore. Than you can use this datastore to install new virtual machine.



Source : https://www.vmware.com/pdf/vsphere4/r41/vsp_41_esxi_i_get_start.pdf

http://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=1025644

http://searchvmware.techtarget.com/tip/VMware-Consolidated-Backup-Adding-an-iSCSI-LUN-to-ESX-Server

http://www.vladan.fr/how-to-connect-esx4-vsphere-to-openfiler-iscsi-nas/

http://www.mattlestock.com/2009/06/esxi-iscsi/

http://www.vmware.com/files/pdf/vmware_esxi_management_wp.pdf




Read more...
 
span.fullpost {display:none;}